Product Testing Accreditations
Polymer Roof Tile Data
- Polymer Roof Tiles meet or exceed all IBC International Building Codes & IEC International Energy Codes & Certifications.
- Polymer Roof Tile Certification & Listings are pending in North America as follows;
Fire ASTM E 108 UL 790 |
Class A or C Burning brand, intermittent flame, and spread of flame. |
UL 2218 Impact | Class 4 Two-inch steel ball weighing 1.2 lbs dropped from 20 feet |
ASTM D3161 same as UL 997 Wind Uplift UL 580 |
Tolerated – speed @ 110mph |
Accelerated Weathering ASTM 4798 | Indistinguishable color change. No appreciable change in tensile strength. |
Freeze-thaw ICC-ES Acceptance Criteria ACO7 section 4.9 | No indication of spalling, crazing, cracking, or other deleterious surface changes. |
ICC-ES AC07 Section 4.4 Loads |
Tolerated an applied load of 200 lbs. |
ASTM D 471 Water Absorption | Virtually no water absorption. |
ASTM D 3462 Nail Pull Through | 140 lbs. Resistance at 32 F 168 lbs. Resistance at 72 F |
ASTM G21 Fungus (algae) | Does not propagate fungus growth |
ASTM D 638 Tensile Strength |
No meaningful reduction of strength. |
TAS-100 | The system tolerates 110 MPH blowing simulated rainwater |
ASTM D6083 & D6694. | Accelerated Aging /Sustainability 50 plus yrs. |
Material Specifications
Compression resistance | 15 mPa (2.175 psi) |
Cross-breaking strength | 10 mPa (1,450 psi) |
Temperature range | -60° … +80°C |
Frost resistance | more than 500 cycles |
Density | 1,500 kg/m3 (93.6 Ib/ft3) |
Flame spread | No flame spread |
Abrasiveness | 0.2 q/m3 |
Water absorption | 0.06% |
Fracture toughness | 3.8 kgf/cm2 |
Biological stability | Resistant to moss and mold spread |
Chemical stability | Does not react with acid and alkaline environment |
UV-resistance | Resistant to UV-radiation – doesn’t lose its color |
Heat conductivity | 2800 J/m2sec |
Category of impact on the organism | Harmless |
Solar Tile Data
- Solar Roof Tiles meet or exceed all IBC International Building Codes & IEC International Energy Codes & Certifications.
- Solar Roof Tile Certification & Listings are pending in North America as follows;
Fire ASTM E 108 UL 790 |
Class A or C Burning brand, intermittent flame, and spread of flame. |
UL 2218 Impact | Class 4 Two-inch steel ball weighing 1.2 lbs dropped from 20 feet |
ASTM D3161 same as UL 997 Wind Uplift UL 580 |
Tolerated – speed @ 110mph |
Accelerated Weathering ASTM 4798 | Indistinguishable color change. No appreciable change in tensile strength. |
Freeze-thaw ICC-ES Acceptance Criteria ACO7 section 4.9 | No indication of spalling, crazing, cracking, or other deleterious surface changes. |
ICC-ES AC07 Section 4.4 Loads |
Tolerated an applied load of 200 lbs. |
ASTM D 471 Water Absorption | Virtually no water absorption. |
ASTM D 3462 Nail Pull Through | 140 lbs. Resistance at 32 F 168 lbs. Resistance at 72 F |
ASTM G21 Fungus (algae) | Does not propagate fungus growth |
ASTM D 638 Tensile Strength |
No meaningful reduction of strength. |
TAS-100 | The system tolerates 110 MPH blowing simulated rainwater |
ASTM D6083 & D6694. | Accelerated Aging /Sustainability 50 plus yrs. |
Testing / Accreditations
UNI 9177 {best} Fire Class A / rating 1 |
Hail – IEC 61215, Class 3 = 1.75″ diameter, 44-gram ice ball, @ 60 mph impact resistance |
Wind Load DIN 1055-4 – 200 mph |
IEC EN 61730, – Harmonized. [not UL listed] |
IEC EN 61215 weather testing including temperature cycling |
IEC EN 61701 – Salt corrosion tested |
CEN/TR 15601 – wind driven rain tested |
CE Certificate – EU safety standards and efficiency |